The temperature and pressure calibration cycle of the socket welding machine usually does not have a fixed standard, but is affected by many factors.
Generally speaking, if the socket welding machine is used frequently and the working environment is relatively harsh, the recommended temperature and pressure calibration cycle is 3-6 months.
If the frequency of use is low and the working environment is good, the calibration cycle can be extended to 6-12 months.
However, the following situations may require a shorter calibration cycle:
The equipment has been repaired or key components such as heating plates, pressure sensors, etc. have been replaced.
The welding quality has fluctuated significantly or is unqualified.
There are major changes in the production process or welding materials.