Electrical safety protection
1. Grounding protection: The Electrofusion welding machine must be grounded to ensure that there is a good electrical connection between the equipment casing and the ground to prevent electric shock accidents caused by leakage.
2. Leakage protection: When used in a humid environment or metal structure, a leakage protector should be installed to prevent electric shock or fire caused by leakage.
3. Overload protection: It has an overload protection function. When the equipment load exceeds the rated value, it automatically cuts off the power supply to protect the equipment and operators.
4. Overvoltage and undervoltage protection: It can detect whether the power supply voltage is within the normal range. When the voltage is too high or too low, it automatically stops working to prevent equipment damage.
Operation safety protection
1. Emergency stop function: It is equipped with an emergency stop button. Once an emergency occurs, the operator can quickly press the button to stop the welding process immediately.
2. Automatic detection and alarm: It has the function of automatically detecting open and short circuit faults in the welding circuit, temperature sensor faults, etc., and can send an alarm signal when an abnormality is detected.
3. Operation error prompt: It can automatically detect operation errors and prompt through the screen to avoid safety accidents caused by misoperation.
Environmental adaptability protection
1. Temperature compensation function: Automatically adjust welding parameters according to ambient temperature to ensure the best welding effect at different ambient temperatures, while preventing safety problems caused by excessively high or low temperatures.
2. Waterproof and moisture-proof design: Although the Electrofusion welding machine itself does not have waterproof performance, the design takes moisture-proof requirements into consideration to adapt to harsh conditions in the field.
Other safety protections
1. Fan protection: The built-in fan is used for heat dissipation to prevent the equipment from overheating. If the fan does not turn, the equipment will automatically stop working to prevent damage caused by overheating.
2. Data storage and traceability: Important parameter data during welding is recorded and stored in real time, which is convenient for later traceability and analysis to ensure welding quality.