I. Load Management
1. Control the duty cycle
Continuous welding time should not exceed 30 minutes, with a mandatory 5-minute break (recommended current ≤140A for a 160A welding machine).
Avoid operating at overload (recommended ≤80%).
2. Parameter Optimization
Adjust the current according to the material thickness (e.g., 120-140A for 3mm steel).
Control the voltage fluctuation range within ±10%.
2. Cooling System Maintenance
1. Air Cooling System
Clean the heat sink dust monthly (compressed air pressure <0.6MPa).
Check the fan speed (normally ≥2500rpm) and any abnormal noise.
2. Water Cooling System
Maintain a water pressure of 0.2-0.4MPa and a flow rate ≥5L/min.
Replace the coolant every six months (conductivity (Efficiency <20μS/cm)
III. Environmental Control
1. Physical Environment
Operating temperature: 15-30°C, humidity: 40-60% RH
Mount at least 50cm from the wall to ensure ventilation
2. Auxiliary Heat Dissipation
Installing an industrial fan or air conditioner for high-temperature environments
Protecting the equipment from direct sunlight
IV. Preventive Maintenance
1. Daily Inspection
Clean welding slag and oxide layers from cable connectors daily
Measure insulation resistance weekly (>2MΩ)
2. Key Component Replacement
Replace electrode tips immediately if wear exceeds 20%
Replace thermal grease every 500 hours (thickness ≤0.2mm)
3. System Inspection
Calibrate the ammeter monthly (error <10%)
Check ground resistance quarterly (<4Ω)